The American Society for Gastrointestinal Endoscopy has released updated infection control guidelines for gastrointestinal endoscopy.
OAK BROOK, Ill. – The American Society for Gastrointestinal Endoscopy (ASGE) has updated its infection control guidelines regarding gastrointestinal (GI) endoscopy. The guidelines note that endoscopy-related infections are a very rare event since the adoption of endoscope reprocessing (cleaning) guidelines. The ASGE infection control guidelines appear in the May issue of GIE: Gastrointestinal Endoscopy, the monthly peer-reviewed scientific journal of the ASGE.
There are many types of endoscopy, including colonoscopy, sigmoidoscopy, gastroscopy, enteroscopy, and esophogogastroduodenoscopy (EGD). ASGE is known as the profession’s leader in setting standards of excellence in endoscopy and is committed to setting the highest-quality standards for GI endoscopy through its safety guidelines and the training of its members so that patients receive the best and safest care possible. The infection control guidelines were prepared by the ASGE Standards of Practice Committee.
"Despite the large number and variety of GI endoscopic procedures performed, documented instances of infectious complications remain rare, with an estimated frequency of 1 in 1.8 million procedures," said Todd H. Baron, MD, FASGE, chair of the ASGE Standards of Practice Committee. "Endoscopy is a safe, well-tolerated and potentially life-saving procedure when practiced by expertly trained physicians who follow the practice guidelines set forth by the ASGE and who adhere to general infection control principles, including aseptic techniques and safe injection practices."
The guidelines are issued to disseminate information to promote understanding, which leads to the prevention of infection as a result of a GI endoscopy. Circumstances in which an endoscopy-related infection might occur are discussed in the document, as are measures to prevent such infection, including endoscope reprocessing, antibiotic prophylaxis, and protection of endoscopy personnel.
The single best protection against patient-to-patient transmission of microorganisms by an endoscopy is stringent reprocessing of endoscopes after use, with careful adherence to the "Multi-Society Guidelines for Reprocessing Flexible Gastrointestinal Endoscopes" issued in 2003. The guidelines define and discuss key concepts in endoscope reprocessing.
Endoscopy personnel may facilitate transmission of infection from patient to patient if they fail to carefully adhere to general infection control principles. In particular, appropriate aseptic techniques and safe injection practices should be followed. Improper reuse of syringes and the use of contaminated multiple dose drug vials have been linked to the transmission of hepatitis B and C between consecutive patients treated at healthcare facilities. Such practices should be avoided, and single use drug vials are recommended. Similarly, use of gloves by healthcare workers was shown to decrease the incidence of Clostridium difficile-associated diarrhea and the point prevalence of asymptomatic C. difficile carriage in inpatients.
Infection Control Guidelines Summary
Transmission of infection as a result of GI endoscopes is extremely rare, and recently reported cases are invariably attributable to lapses in currently accepted endoscope reprocessing protocols or to defective equipment.
Endoscopes should undergo high-level disinfection as recommended by governmental agencies and all pertinent professional organizations for the reprocessing of GI endoscopes.
Extensive training of staff involved in endoscopic reprocessing is mandatory for quality assurance and for effective infection control.
General infection control principles should be adhered to at the endoscopy unit.
ASGE Guidelines
"Infection Control During GI Endoscopy" is available at: http://asge.org/WorkArea/showcontent.aspx?id=4300
"Antibiotic Prophylaxis for GI Endoscopy" can be accessed at: http://asge.org/WorkArea/showcontent.aspx?id=4298
"Multi-Society Guidelines for Reprocessing Flexible Gastrointestinal Endoscopes" can be accessed at: http://asge.org/WorkArea/showcontent.aspx?id=3376
Source: American Society for Gastrointestinal Endoscopy
The Leapfrog Group and the Positive Effect on Hospital Hand Hygiene
November 21st 2024The Leapfrog Group enhances hospital safety by publicizing hand hygiene performance, improving patient safety outcomes, and significantly reducing health care-associated infections through transparent standards and monitoring initiatives.
Infection Intel: Revolutionizing Ultrasound Probe Disinfection With Germitec's Chronos
November 19th 2024Learn how Germitec’s Chronos uses patented UV-C technology for high-level disinfection of ultrasound probes in 90 seconds, enhancing infection control, patient safety, and environmental sustainability.
The Importance of Hand Hygiene in Clostridioides difficile Reduction
November 18th 2024Clostridioides difficile infections burden US healthcare. Electronic Hand Hygiene Monitoring (EHHMS) systems remind for soap and water. This study evaluates EHHMS effectiveness by comparing C difficile cases in 10 hospitals with CMS data, linking EHHMS use to reduced cases.
Why Clinical Expertise Is the Cornerstone to Your Most Profitable Business Line
November 14th 2024Perioperative nurses bring vital skills in patient safety, infection control, and quality improvement. They enhance surgical outcomes and support health care systems during complex, high-risk procedures.