Salmonella and listeria are among the most widely distributed and deadliest causes of foodborne infections. Their rapid and reliable detection on food and industrial food processing equipment is very important. In the journal Angewandte Chemie, scientists have introduced a new, ultrasensitive, chemiluminescence-based method for the direct detection of Salmonella and Listeria monocytogenes. Because of the simplicity and sensitivity, this test is significantly faster than conventional methods and can be carried out in the field.

It is estimated that about a million people per year are infected with salmonella infections in the U.S. alone. Of these, 380 die. Infections with listeria can also often be fatal. Current testing methods usually require the growth of bacterial cultures in a containment laboratory. A conclusive result based on standard diagnostic techniques generally takes two to six days.

Researchers working with Urs Spitz and Doron Shabat at the University of Tel Aviv, Nemis Technologies AG (Zurich, Switzerland), Zurich University of Applied Sciences, and Biosynth AG (Staad, Switzerland) have now introduced a new and efficient method for the ultrasensitive and significantly faster detection of Salmonella and Listeria. The method is based on chemiluminescence--the emission of light resulting from a chemical process. The simplicity of the tests allows for both enrichment of the bacteria and their detection in a test tube, with no further sample preparation, so no containment laboratory is required. The chemiluminescence probes have proven to be about 600 times more sensitive than conventional fluorescence probes.

The success of this technique is due to two specially developed probe molecules made by combining a luminescent substance (a phenoxy-dioxetane) with a "trigger". In this form the probe does not light up. The trigger is tailored to the bacteria to be detected: it is recognized by a specific enzyme produced by the pathogen--a special esterase in the case of Salmonella and a special phospholipase C for Listeria--that splits it from the luminescent part. This initiates a chemical reaction that causes the luminescent molecule to split off more pieces. The energy released by the reaction is emitted in the form of a very intense green glow. Tests with various bacteria demonstrated that the probe tailored to Listeria test only reacts to Listeria monocytogenes, not to other, non-pathogenic, strains of listeria. The intensity of the glow can be used to quantify the concentration of bacteria. The tests are so sensitive that, for example, a count of ten salmonella can be detected within six hours of enrichment. Even dried bacteria can be swabbed from surfaces and detected.

The researchers are confident that their new method can be used more broadly to develop specific chemiluminescence probes for other bacteria.

Source: Wiley

Recent Videos
Infection Control Today's Infection Intel: Staying Ahead With Company Updates and Product Innovations.
COVID-19 presentations at IDWeek in Las Angeles, California by Invivyd.   (Adobe Stock 333039083 by Production Perig)
Long COVID and Other Post-Viral Syndromes
Meet Jenny Hayes, MSN, RN, CIC, CAIP, CASSPT.
Infection Control Today Editorial Advisory Board: Fibi Attia, MD, MPH, CIC.
Andrea Thomas, PhD, DVM, MSc, BSc, director of epidemiology at BlueDot
mpox   (Adobe Stock 924156809 by Andreas Prott)
Meet Alexander Sundermann, DrPH, CIC, FAPIC.
Veterinary Infection Prevention
Related Content