Study Confirms Safety of Forced-Air Warming

Article

The use of forced-air warming to maintain patient normothermia and help prevent surgical site infections (SSIs) and other complications does not disturb laminar air flow in operating rooms or compromise the protection of the surgical site, a newly published study has concluded.(1)

The addition of this research to the significant body of existing science should leave no doubts regarding the safety of forced-air warming when used in laminar flow conditions, says Bob Buehler, vice president of 3Ms patient warming business.  While makers of competing technologies continue their efforts to deceive heathcare practitioners and disrupt our business, we will rely on the evidence and our 24-year history of safe, effective care to speak on our behalf.

This is positive news for orthopedic surgeons, a group especially vigilant about contaminants entering the surgical site. They often perform surgery in suites equipped with laminar air flow ventilation systems. Laminar air flow is designed to reduce airborne bacteria that may cause SSIs by dispensing highly filtered air over the surgical field.

At least six independent, peer-reviewed studies have demonstrated that forced-air warming does not increase bacteria dispersion near the patient.(2-7) Independent randomized control studies have shown that perioperative temperature management with forced-air warming actually decreases SSI risk in patients.(8-8)

A peer-reviewed study published online ahead of print by Anesthesia & Analgesia extends those results by showing that forced-air warming systems do not impair operating room air quality, with or without laminar flow ventilation.(1)

The authors evaluated the effect of forced-air warming on laminar air flow performance in class 1a operating rooms at two hospitals in the Netherlands. The testing methodology met a rigorous European standard, DIN 1946-4:2008-12, that includes quantitative testing of particle counts and was conducted by an independent organization.

Two forced-air warming blankets were tested: a 3M Bair Hugger model 522 upper-body blanket and a 3M Bair Hugger model 635 underbody blanket. At the same time, the concentration of particles at the surgical site was assessed at a test point just above the volunteers abdomen. Use of the 3M Bair Hugger blankets caused no statistically significant difference in particle counts, regardless of whether the forced-air warming unit was set to off, ambient air or high heat settings.

In all cases, the particle concentration at the test point was reduced 3-log to 5-log (1,000x to 100,000x) compared to background particulate levels in the room. This far surpassed the 2-log reduction required by the European performance standard. 
The authors also deployed a vapor generator to assess airflow patterns above the patient with the forced-air blower set to high and the laminar flow system activated. Neither the forced-air warming blanket nor the forced-air blower generated upward air that interfered with the normal unidirectional stream of the laminar air flow system.

The studys conclusions align with published computational fluid dynamic models that show the downward stream of laminar air flow effectively reduces particle concentrations around the operative site. (10)

The authors conclude by confirming that, activation of forced-air warming does not reduce operating room air quality, even during laminar flow ventilation.(1)

References
1. Sessler DI, Olmsted RN, Kuelpmann R.  Forced-Air Warming Does Not Worsen Air Quality in Laminar Flow Operating Rooms [Published online ahead of print September 29, 2011].  Anesth Analg. 2011 Sep 29; PMID 21965373.  http://www.anesthesia-analgesia.org/content/early/2011/09/28/ANE.0b013e318230b3cc.full.pdf.  Accessed October 26, 2011.
2. Avidan MS, Jones N, Ing R, Khoosal M, Lundgren C, Morrell DF. Convection warmers: not just hot air. Anaesthesia 1997;52:10736.
3. Huang JK, Shah EF, Vinodkumar N, Hegarty MA, Greatorex RA. The Bair Hugger patient warming system in prolonged vascular surgery: an infection risk? Crit Care 2003;7:R136.
4. Moretti B, Larocca AM, Napoli C, Martinelli D, Paolillo L, Cassano M, Notarnicola A, Moretti L, Pesce V. Active warming systems to maintain perioperative normothermia in hip replacement surgery: a therapeutic aid or a vector of infection? J Hosp Infect 2009;73:5863.
5. Sharp RJ, Chesworth T, Fern ED. Do warming blankets increase bacterial counts in the operating field in a laminar-flow theatre? J Bone Joint Surg Br 2002;84:4868.
6. Tumia N, Ashcroft GP. Convection warmers: a possible source of contamination in laminar airflow operating theatres? J Hosp Infect 2002;52:1714.
7. Zink RS, Iaizzo PA. Convective warming therapy does not increase the risk of wound contamination in the operating room. Anesth Analg 1993;76:503.
8. Kurz A, Sessler DI, Lenhardt R. Perioperative Normothermia to reduce the incidence of surgical-wound infection and shorten hospitalization. N Engl J Med 1996:334:1209-15.
9. Melling AC, Ali B, Scott EM, Leaper DJ. Effect of preoperative warming on the incidence of wound infection after clean surgery: a randomized controlled trial. Lancet 2001;358:876-80.
10. Memarzadeh F, Manning A. Comparison of operating room ventilation systems in the protection of the surgical site. ASHRAE Trans 2002;108:315.

 

Recent Videos
Meet Jenny Hayes, MSN, RN, CIC, CAIP, CASSPT.
Meet Shannon Simmons, DHSc, MPH, CIC.
Clostridioides difficile  (Adobe Stock 260659307 by gaetan)
Weekly Rounds with Infection Control Today
Association for Professionals in Infection Control and Epidemiology  (Image credit: APIC)
Patient Safety: Infection Control Today's Trending Topic for March
Infection Control Today's Trending Topic for March: Patient Safety
Infection Control Today® (ICT®) talks with John Kimsey, vice president of processing optimization and customer success for Steris.
Picture at AORN’s International Surgical Conference & Expo 2024
Related Content