Researchers Evaluate Pulsed-Xenon Room Disinfection Device

Article

Healthcare-acquired infections with methicillin-resistant Staphylococcus aureus (MRSA) are a significant cause of increased mortality, morbidity and additional healthcare costs in United States. Surface decontamination technologies that utilize pulsed xenon ultraviolet light (PPX-UV) may be effective at reducing microbial burden. The purpose of this study by Jinadatha, et al. (2014) was to compare standard manual room-cleaning to PPX-UV disinfection technology for MRSA and bacterial heterotrophic plate counts (HPC) on high-touch surfaces in patient rooms.

Rooms vacated by patients that had a MRSA-positive polymerase chain reaction or culture during the current hospitalization and at least a two-day stay were studied. Twenty rooms were then treated according to one of two protocols: standard manual cleaning or PPX-UV. This study evaluated the reduction of MRSA and HPC taken from five high-touch surfaces in rooms vacated by MRSA-positive patients, as a function of cleaning by standard manual methods vs a PPX-UV area disinfection device.

Colony counts in 20 rooms (10 per arm) prior to cleaning varied by cleaning protocol: for HPC, manual (mean = 255, median = 278, q1-q3 132-304) vs PPX-UV (mean = 449, median = 365, q1-q3 332-530), and for MRSA, manual (mean = 127; median = 28.5; q1-q3 8-143) vs PPX-UV (mean = 108; median = 123; q1-q3 14-183). PPX-UV was superior to manual cleaning for MRSA (adjusted incident rate ratio [IRR] = 7; 95% CI <1-41) and for HPC (IRR = 13; 95% CI 4-48).

The researchers concludee that PPX-UV technology appears to be superior to manual cleaning alone for MRSA and HPC. They add that incorporating 15 minutes of PPX-UV exposure time to current hospital room cleaning practice can improve the overall cleanliness of patient rooms with respect to selected micro-organisms. Their research was published in BMC Infectious Diseases

Reference: Jinadatha C, Quezada R, Huber TW, Williams JB, Zeber JE and Copeland LA. Evaluation of a pulsed-xenon ultraviolet room disinfection device for impact on contamination levels of methicillin-resistant Staphylococcus aureus. BMC Infectious Diseases 2014, 14:187  doi:10.1186/1471-2334-14-187

Recent Videos
A veterinarian in a protective suit takes tests on animals on a farm.   (Adobe Stock 829620654 by Яна Ерік Татевосян)
Neatly Stacked Hospital Linen, Clean Fabric in Turquoise, White, and Blue Hues. Created by AI.  (Adobe Stock 1103251410 by HQAsset)
Chicago’s Dental Society Midwinter Meeting  (Adobe Stock 7622055 by abricotine)
Cameron Memorial Community Hospital Series With ICT
Cameron Memorial Community Hospital series with ICT  (Image Credit: CMCH)
Cameron Memorial Community Hospital series with ICT  (Image Credit: CMCH)
Cameron Memorial Community Hospital series with ICT (Image Credit: CMCH)
Cameron Memorial Community Hospital series with ICT (Image Credit: CMCH)
Cameron Memorial Community Hospital series with ICT (Image Credit: CMCH)
Infection Control Today's Infection Intel: Staying Ahead With Company Updates and Product Innovations.
Related Content